APC APDU10351SM power distribution unit (PDU) 48 AC outlet(s) 0U Black
SKU
APDU10351SM
Login for pricing
Out Of Stock - Contact for availability
50/60 Hz, 200 - 240VAC, Load Capacity 8600VA
- Maximum Outlet Density All models include 40, 42, or 48 outlets
- Space Saving
- High Power Capacity Models now available to provide up to 34.6kW
- APC Locking Power Cord Compatible Optional AP8700 power cords will fit into any standard IEC receptacle or power inlet
- Circuit Breaker Monitoring
- Alternating Phase
- 60ºC (140ºF) Operating Temperature
- Rack PDUs cascaded together via the two ethernet ports on each PDU allow Network Management Cards (NMC) to continue functioning in the event of an AC power loss to a given PDU
- Hydraulic Magnetic Circuit Breakers
- Live Swap Network Management Card
- Environmental Sensor Support
- Color LCD Display
- Dual Network Ports
APC NetShelter Rack PDU Advanced, Switched Metered Outlet, 8.6kW, 3PH, 208V 30A, L21-30P, 48 Outlet
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected.
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected.
Design | |
---|---|
On/off switch | No |
Type | Single-phase |
PDU types | Switched |
Mounting | Vertical |
Display | LCD |
Product colour | Black |
Certification | CSA C22.2 No 62368-1, FCC part 15 subpart B, UL 62368-1 |
Rack capacity | 0U |
Ports & interfaces | |
AC outlets quantity | 48 AC outlet(s) |
AC outlet types | C13 coupler, C15 coupler, C19 coupler, C21 coupler |
Features | |
Certification | CSA C22.2 No 62368-1, FCC part 15 subpart B, UL 62368-1 |
Daisy chain | Yes |
Ergonomics | |
Display | LCD |
Power | |
---|---|
Nominal input voltage | 208 V |
Nominal output voltage | 208 V |
Output voltage | 208 V |
Maximum current | 24 A |
Maximum total current draw per phase | 24 A |
Maximum input current per phase | 30 A |
Load capacity | 8600 VA |
AC input frequency | 50 - 60 Hz |
Weight & dimensions | |
Weight | 9.4 kg |
Width | 56 mm |
Depth | 75 mm |
Height | 1780 mm |
Package width | 208 mm |
Package depth | 116 mm |
Package height | 1980 mm |
Package weight | 12.4 kg |
Packaging data | |
Package width | 208 mm |
Package depth | 116 mm |
Package height | 1980 mm |
Package weight | 12.4 kg |
Operational conditions | |
Operating temperature (T-T) | 23 - 140 °C |
Storage temperature (T-T) | -25 - 65 °C |
Storage relative humidity (H-H) | 5 - 95% |
Operating relative humidity (H-H) | 5 - 95% |
Operating altitude | 0 - 3048 m |
Non-operating altitude | 0 - 15240 m |